Exadata Part Replacement: Quick Notes
Table of Contents
This page covers replacing failed hardware on Exadata storage servers (cells) and database servers. First decide whether the part is hot-swappable or needs a server shutdown. If it needs a shutdown, the storage server or database server must be taken out of service cleanly so that ASM and Clusterware are not affected.
1. Hot-Swappable vs Shutdown-Required Components
| Component | Replacement Type | Notes |
|---|---|---|
| Hard Disk (LUN / Disk) | Hot Swappable | Replace only when the OK-to-Remove LED is lit. After replacement, MS recreates the LUN, cell disk and grid disks, and ASM resyncs automatically. |
| Flash Disk / Flash Card | Hot Swappable (X7 and later) | On X6 and earlier, the PCIe flash cards of High Capacity storage servers need a shutdown. The NVMe flash drives of Extreme Flash storage servers are hot-pluggable on all models. |
| M.2 System Disk (X7 and later) | Hot Swappable | Two internal M.2 devices hold the system area. They can be replaced with the server powered on, and the system software rebuilds the mirror automatically. |
| Fan Module | Hot Swappable | Complete the swap promptly to keep airflow and cooling intact. |
| Power Supply Unit (one of two) | Hot Swappable | Replace one PSU at a time. First confirm the other PSU and both PDU feeds are healthy. |
| DIMM (Memory) | Shutdown Required | Applies to both DB servers and storage servers. |
| PMEM Module (X8M-2 / X9M-2 storage servers) | Shutdown Required | Follow the model-specific procedure in the Maintenance Guide. |
| CPU | Shutdown Required | Oracle Field Engineer normally performs this. |
| PCIe Cards (InfiniBand HCA / RoCE NIC, RAID HBA) | Shutdown Required | Flash cards on X7 and later are the exception (see above). |
| Motherboard | Shutdown Required | Oracle Field Engineer normally performs this. |
Note: Which parts are customer-replaceable (CRU) or hot-pluggable varies by model. Always confirm in the Oracle Exadata Database Machine Maintenance Guide for your exact model and image version.
2. Pre-Checks (Always)
- Confirm the fault:
cellcli -e list alerthistoryon a cell,dbmcli -e list alerthistoryon a DB server, andshow faultyin ILOM. - Check that an Oracle SR exists. ASR normally raises it automatically for hardware faults.
- Collect diagnostics for the SR:
/opt/oracle.SupportTools/sundiag.sh - Service only one storage server or DB server at a time.
- Make sure no other cell or disk is already offline or failed. This is critical on Normal redundancy disk groups.
- Check
disk_repair_time. If the cell will be down longer than this, ASM drops its disks and a full rebalance follows.
SELECT dg.name AS diskgroup, a.value AS disk_repair_time
FROM v$asm_diskgroup dg, v$asm_attribute a
WHERE dg.group_number = a.group_number
AND a.name = ‘disk_repair_time’;
Note: The default is 12 hours in ASM 12.1 and later (3.6 hours in 11.2). Check the actual value on your system.
3. Hot-Swap Disk Replacement (Storage Server)
cellcli -e list physicaldisk attributes name,slotNumber,status
cellcli -e list physicaldisk <disk_name> detail
cellcli -e list alerthistory
Β
# Replace the disk (OK-to-Remove LED lit), then verify
cellcli -e list physicaldisk attributes name,status
cellcli -e list lun attributes name,status
cellcli -e list celldisk attributes name,status
cellcli -e list griddisk attributes name,status,asmmodestatus
After replacement the cell recreates the cell disk and grid disks automatically, and ASM adds them back and rebalances. Monitor with SELECT * FROM gv$asm_operation; in the ASM instance. No manual grid disk deactivation is needed for a hot-swap disk.
Note: For a hot-pluggable flash device, check that its status is failed - dropped for replacement before you remove it. If it is in another state, first prepare it with cellcli -e alter physicaldisk <disk_name> drop for replacement.
4. Before Replacement: Storage Server (Shutdown Required)
WARNING: Always check ASM rebalance activity before making grid disks inactive. Proceed only if asmdeactivationoutcome is Yes for all grid disks. If it is not, stop and find out why. Never force it.
Step 1 – ASM instance (SQL): no rebalance should be running
— Expected: no rows selected. If rows exist, wait for the rebalance to finish.
Step 2 – Storage server (CellCLI): verify it is safe to deactivate
Β
# Quick check – this should return nothing
cellcli -e “list griddisk attributes name,asmdeactivationoutcome where asmdeactivationoutcome != ‘Yes'”
Step 3 – Deactivate grid disks and verify
cellcli -e list griddisk attributes name,asmmodestatus,asmdeactivationoutcome,status
# Expected: status = inactive for all grid disks (ASM disks go OFFLINE)
Step 4 – Stop cell services and power off
service celld stop # optional – shutdown also stops cell services
shutdown -h now # or: stop /SYS from ILOM
Note: On newer images you can use systemctl instead of service. Make sure the server is fully powered off (check the ILOM or LEDs) before replacing the part.
5. Before Replacement: Database Server (Shutdown Required)
crsctl check crs
crsctl stat res -t # confirm the other nodes are up and services are available
crsctl stop crs # stops Clusterware, ASM and database instances on this node
shutdown -h now
Note: Run crsctl from the Grid Infrastructure home. On virtualized systems (Oracle VM or KVM), shut down the guest VMs first, then the host.
6. After Replacement: Storage Server
Power on the server, wait for it to boot, then run:
cellcli -e list cell attributes name,cellsrvStatus,msStatus,rsStatus # all should be running
cellcli -e list griddisk attributes name,asmmodestatus,asmdeactivationoutcome,status
Β
cellcli -e alter griddisk all active
Β
cellcli -e list griddisk attributes name,asmmodestatus,asmdeactivationoutcome,status
Wait for the ASM resync to finish (ASM instance):
— Repeat until no rows are returned
Final health check (CellCLI):
cellcli -e list physicaldisk attributes name,status
cellcli -e list alerthistory
WARNING: Do not start work on the next cell until all grid disks show asmmodestatus = ONLINE and there are no rows in gv$asm_operation. Also confirm in ILOM that the fault has cleared.
7. After Replacement: Database Server
crsctl config crs # confirm autostart is enabled
crsctl check crs
crsctl stat res -t # ASM, listeners, instances and services should come ONLINE
# If Clusterware did not start on its own:
crsctl start crs
Note: Also confirm in ILOM that the fault has cleared, and run dbmcli -e list alerthistory for new alerts.
8. Grid Disk Status Reference
| Attribute / Value | Meaning |
|---|---|
status = active / inactive | Whether the grid disk is available to ASM |
asmmodestatus = ONLINE | Disk is online in ASM and fully usable |
asmmodestatus = SYNCING | Disk is back online and ASM is resyncing it. Wait for ONLINE. |
asmmodestatus = OFFLINE | Disk is offline in ASM (the repair timer is running) |
asmmodestatus = UNUSED | Grid disk is not in use by ASM (for example, inactive) |
asmdeactivationoutcome = Yes | Safe to deactivate. ASM stays available with this disk offline. |
asmdeactivationoutcome = (any other text) | Not safe. Taking this cell down could dismount a disk group. Do not proceed. |
9. Quick Troubleshooting
| Symptom | What to Check |
|---|---|
asmdeactivationoutcome is not Yes | Another disk or cell is offline, or a rebalance or resync is running. Fix or wait first. |
| Grid disks stay in SYNCING for a long time | gv$asm_operation for progress and estimated time. Resync time depends on the amount of data changed while the cell was down. |
Cell was down longer than disk_repair_time | ASM may have dropped its disks. Check v$asm_disk and v$asm_operation, and re-add the disks following Oracle Support guidance. |
| New disk is not visible after a hot swap | MS status, list physicaldisk, list lun and list alerthistory. Check that the disk is seated correctly. |
| Fault still shown in ILOM after replacement | Re-check the part is seated, wait a few minutes, then run show faulty. Update the SR if it persists. |
| DB server’s Clusterware did not start | crsctl check crs, crsctl config crs, the fabric link status, and the alert log in the Grid home. |
10. Key Rules
- Service one server at a time.
- Never deactivate grid disks unless
asmdeactivationoutcome = Yesfor all of them. - Never start the next cell until the resync is complete and all grid disks are ONLINE.
- Keep the downtime shorter than
disk_repair_time. - For hot-swap disks, do not manually deactivate grid disks. Replace the disk and let MS and ASM handle it.
- Run EXAchk after the work to confirm the system is healthy.