Oracle Exadata Rack Size
| Rack Size | DB Servers | Storage Servers | Typical Use |
|---|---|---|---|
| Eighth Rack | 2 | 3 | Dev / Test / DR |
| Quarter Rack | 2 | 3 | Small–Medium Production |
| Half Rack | 4 | 7 | Medium–Large Production |
| Full Rack | 8 | 14 | Large / Mission Critical |
Note: An Eighth Rack has the same number of servers as a Quarter Rack, but only half of the CPU cores, disks and flash are enabled. Starting with X8M, Exadata is sold as elastic configurations (a base system of 2 DB + 3 storage servers, plus additional DB and storage servers), so fixed rack sizes mainly apply to X8 and earlier.
Exadata Private Network Fabric (X5-2 to X11M)
| Exadata Model | Network Type | Speed Per Port | Ports Per Server | Redundancy |
|---|---|---|---|---|
| X5-2 | InfiniBand (QDR) | 40 Gb/s | 2 | Active-passive bond (bondib0) |
| X6-2 | InfiniBand (QDR) | 40 Gb/s | 2 | Active-passive bond (bondib0) |
| X7-2 | InfiniBand (QDR) | 40 Gb/s | 2 | Active-passive bond (bondib0) |
| X8-2 | InfiniBand (QDR) | 40 Gb/s | 2 | Active-passive bond (bondib0) |
| X8M-2 | RoCE (RDMA over Converged Ethernet) | 100 Gb/s | 2 | One port to each leaf switch |
| X9M-2 | RoCE | 100 Gb/s | 2 | One port to each leaf switch |
| X10M-2 | RoCE | 100 Gb/s | 2 | One port to each leaf switch |
| X11M | RoCE | 100 Gb/s | 2 | One port to each leaf switch |
Note: On X8 and earlier, bondib0 runs in active-backup mode, so one port carries traffic and the other is a standby. This is why a “bonded speed” of 2 × the port speed is not accurate. On X8M and later, interface names and bonding details (for example re0/re1, stre0/stre1, clre0/clre1) vary by model and image version. Verify with ip -br addr and oifcfg getif.
Exadata Networking Overview
Oracle Exadata uses a high-speed, low-latency internal network that connects Database Servers, Storage Servers (Cells) and Switches. This network enables features such as Smart Scan (iDB), ASM rebalance, RAC Cache Fusion and high-speed data transfer. Every Exadata system has three logical networks: Management, Client and the Private RDMA Fabric.

| Network | Connects | Switch | Typical Interface |
|---|---|---|---|
| Management | Admin access to servers, ILOM, switches and PDUs | Cisco Ethernet admin switch | eth0, ILOM |
| Client | Applications and users to DB servers | Customer data center network | bondeth0 |
| Private RDMA Fabric | DB to storage, and DB to DB (RAC) | InfiniBand (X8 and earlier) or RoCE (X8M and later) leaf switches | bondib0 or RoCE interfaces |
1. Client Network
| Feature | Description |
|---|---|
| Purpose | Application and user connections to the database |
| Traffic | SQL queries, application requests, listener, SCAN and VIP traffic, backups to external targets |
| Network Type | Standard Ethernet. DB servers provide 1/10 GbE copper and 10/25 GbE optical ports, depending on the model and the options ordered. |
| High Availability | Two ports bonded as bondeth0 (typically active-backup), connected to the customer’s switches |
| Example Flow | Application → Client Network → SCAN Listener → Local Listener → RAC Instance |
2. Management Network
| Feature | Description |
|---|---|
| Purpose | Administration and monitoring of all rack components |
| Connected Components | DB server and cell management ports (eth0), ILOMs, fabric switches and PDUs |
| Switch | One Cisco Ethernet admin switch per rack (the model varies by generation) |
| Typical Use | SSH access, ILOM console, patching with patchmgr, monitoring and Enterprise Manager |
3. RAC Private Interconnect
The private interconnect is used for communication between RAC database nodes. On Exadata it runs over the same RDMA fabric that connects the database servers to the storage servers.
| Usage | Description |
|---|---|
| Cache Fusion | Transfers data blocks and lock messages between RAC instances (GCS/GES) |
| Cluster Heartbeat | Clusterware (CSS) network heartbeat between nodes, used to detect node failure |
| Parallel Query | Data exchange between parallel execution servers on different nodes |
Networking technology by model:
| Exadata Model | Networking Technology |
|---|---|
| X2 – X8 | InfiniBand QDR, 40 Gb/s per port |
| X8M and later | RoCE (RDMA over Converged Ethernet), 100 Gb/s per port |
4. Storage Network (Database → Storage Cells)
Database nodes communicate with Exadata storage servers over the RDMA fabric using the iDB protocol. The database servers find the cells through the IP addresses listed in /etc/oracle/cell/network-config/cellip.ora.
| Feature | Description |
|---|---|
| Smart Scan | SQL filtering and column projection pushed to storage servers, and only the required data is returned |
| Block Reads and Writes | Fast I/O between ASM/RDBMS instances and storage cells |
| ASM Rebalance | High-speed disk rebalance and resync operations, including data transfers directly between cells |
| Flash Cache Reads | Access to flash storage with very low latency |
| PMEM / XRMEM Access (X8M and later) | Database servers read cell memory directly using RDMA, bypassing the storage server CPU |
| Offloaded Backup | RMAN incremental backup filtering is done on the cells, so less data crosses the network |
5. Exadata Network Architecture
| Component | Typical Full Rack Count |
|---|---|
| Database Servers | 8 |
| Storage Servers | 14 |
| InfiniBand Switches (X8 and earlier) | 3 (2 leaf + 1 spine) |
| RoCE Network Fabric Switches (X8M and later) | 2 (leaf, redundant) |
| Cisco Ethernet Admin Switch | 1 |
| PDUs | 2 |
Application
↓ (Client Network - bondeth0)
DB Server 1 ... DB Server N ←→ RAC Private Interconnect (same RDMA fabric)
↓ (Port 1 / Port 2, one to each leaf switch)
Leaf Switch 1 Leaf Switch 2 (InfiniBand or RoCE)
↓
Storage Cell 1 ... Storage Cell N
Admin Switch ←→ eth0 / ILOM of every server, fabric switches and PDUs
6. Important Exadata Networking Commands
Common (all models):
ip -br addr ip -br link cat /proc/net/bonding/bondeth0 cat /etc/oracle/cell/network-config/cellip.ora # on DB servers: cell IPs cat /etc/oracle/cell/network-config/cellinit.ora # on cells: local fabric IPs /opt/oracle.cellos/ipconf -verify # validate network configuration oifcfg getif # Grid Infrastructure: networks in use
InfiniBand systems (X8 and earlier):
cat /proc/net/bonding/bondib0 ibstat ibstatus iblinkinfo ibswitches ibhosts rds-ping <peer_ib_ip>
RoCE systems (X8M and later):
rdma link ibdev2netdev ethtool <roce_interface> | grep -i -E "speed|link detected"
Check all servers at once (dcli, from a DB server):
dcli -g all_group -l root "ibstat | grep -E 'State|Rate'" # InfiniBand dcli -g all_group -l root "rdma link" # RoCE dcli -g all_group -l root "ip -br addr"
From the database or ASM instance (SQL):
SELECT inst_id, name, ip_address, source FROM gv$cluster_interconnects; SELECT cell_path FROM v$cell;
Note: InfiniBand commands such as ibstat and iblinkinfo do not apply to RoCE systems. Interface names differ between models and image versions, so run ip -br link first.
7. Quick Network Troubleshooting
| Symptom | What to Check |
|---|---|
| ASM cannot see grid disks | Contents of cellip.ora, ping the cell IPs, and cellcli -e list griddisk status |
| Link down or port flapping | ibstat / rdma link, cables and switch port status, and the bond’s active slave |
| High interconnect latency or gc waits | AWR (gc waits, interconnect statistics), rds-ping (InfiniBand), and port error counters |
| Clients cannot connect | bondeth0 status, srvctl config scan, listener status and the customer switch ports |
| Cannot reach a server’s admin interface | Admin switch, eth0 and ILOM connectivity |
Tip: Run Oracle EXAchk regularly. It validates network configuration against Oracle best practices.
8. Key Advantages of Exadata Networking
| Feature | Benefit |
|---|---|
| RDMA | Ultra-low-latency communication with minimal CPU overhead |
| High Bandwidth | Faster query processing and rebalance operations |
| Redundant Leaf Switches | High availability, with no single point of failure in the fabric |
| Redundant Ports and Bonded Interfaces | Network failover (client network and InfiniBand bond) and multipathing |
| Separate Networks | Management, client and storage/RAC traffic are isolated from each other |
| Pre-configured and Pre-cabled | Consistent, validated network design for every Exadata deployment |