Exadata Part Replacement Runbook

Exadata Part Replacement – Quick Notes

Hot Swappable Components

ComponentReplacement Type
LUN / DiskHot Swappable
FanHot Swappable
Single Power SupplyHot Swappable
Flash Disk (From X7)Hot Swappable
DIMMShutdown Required
MotherboardShutdown Required

Before Replacement (If Shutdown Required)

**** Always verify ASM rebalance activity before making grid disks inactive.
select * from gv$asm_operation;
cellcli -e list griddisk attributes name, asmmodestatus, asmdeactivationoutcome, status 
cellcli -e alter griddisk all inactive 
cellcli -e list griddisk attributes name, asmmodestatus, asmdeactivationoutcome, status 
service celld status 
service celld stop 
shutdown -h now

After Replacement

service celld status 
cellcli -e list griddisk attributes name, asmmodestatus, asmdeactivationoutcome 
cellcli -e alter griddisk all active
cellcli -e list griddisk attributes name, asmmodestatus, asmdeactivationoutcome

select * from gv$asm_operation;

Caution: Your use of any information or materials on this website is entirely at your own risk. It is provided for educational purposes only. It has been tested internally, however, we do not guarantee that it will work for you. Ensure that you run it in your test environment before using.